Rebel elevator horns

Converted from Wildcat! database. (read only)
Locked
allsure

Rebel elevator horns

Post by allsure » Fri Feb 17, 2012 9:02 pm

G'day

I am fitting the elevator control horns and have found a few problems.

1. When tighten the bolts holding the bearing blocks onto the FUS 31, the blocks distort so much that the horns bind up.

2. I also noticed that the FUS 31 oilcans quite a bit under the control horns.

Has anyone encountered this?

I would appreciate some assistance.


Thanks and regards

Ian Donaldson

Legeorgen

Rebel elevator horns

Post by Legeorgen » Fri Feb 17, 2012 9:02 pm

Ian,

I experienced the same thing with the elevator control horn. I believe I was
over torque the bolts. They are AN3 bolts (if I remember correctly) and
require only 15 to 20 inch lb. of torque. It never feels right to me when I
tighten AN3 bolts because they never seem tight enough, so I always want to
over torque them. The FUS 31 will still oil can some but I assume it is not a
problem. Maybe one of the other more experienced build can help you there.

Bruce G 357R




-----------------------------------------------------------------
List archives located at: https://mail.dcsol.com/login
username "rebel" password "builder"
Unsubscribe: rebel-builders-unsubscribe@dcsol.com
List administrator: mike.davis@dcsol.com
-----------------------------------------------------------------

Graeme & Britta Weck

Rebel elevator horns

Post by Graeme & Britta Weck » Fri Feb 17, 2012 9:02 pm

Legeorgen@cs.com wrote:
*-------------------------------------------------------------------------*
The list archives are located at:
http://www.dcsol.com:81/public/default.htm
username: rebel password: builder
*-------------------------------------------------------------------------*
Ian,

I experienced the same thing with the elevator control horn. I believe I was
over torque the bolts. They are AN3 bolts (if I remember correctly) and
require only 15 to 20 inch lb. of torque. It never feels right to me when I
tighten AN3 bolts because they never seem tight enough, so I always want to
over torque them. The FUS 31 will still oil can some but I assume it is not a
problem. Maybe one of the other more experienced build can help you there.

Bruce G 357R

*-------------------------------------------------------------------------*
You have received this message because you have subscribed to the
murphy-rebel mailing list.
To unsubscribe from this list, send an e-mail to: list-server@dcsol.com
with "unsubscribe murphy-rebel" in the body of the message.
For assistance contact mike.davis@dcsol.com
*-------------------------------------------------------------------------*
Ian, I had the same problem as the the blocks seem to both angle inwards
. I have put a angle across front and back of the horn this holds the
blocks up straight and gives me something to mount a stop on ,hope this
make sense
Regards
Graeme 647R



-----------------------------------------------------------------
List archives located at: https://mail.dcsol.com/login
username "rebel" password "builder"
Unsubscribe: rebel-builders-unsubscribe@dcsol.com
List administrator: mike.davis@dcsol.com
-----------------------------------------------------------------


Locked